IO-100 Series Submittal Data

IO-100 SUBMITTAL
SD061213
RL: 3
RD: nov2016
4
Note: Ensure mounting height in any location is sufficient to prevent patrons from coming in
contact with heater, and clearance to combustible material is maintained.
MINIMUM CLEARANCE TO COMBUSTIBLES
QTY Application MODEL
Ends Under HORIZONTAL UP TO MAXIMUM 30° ANGLE
E U A S MH CH T B F MA CA
OUTDOOR IO-135 14” - 13” 14” 108” 133” 17” 9” 60” 102” 133”
OUTDOOR IO-150 14” - 16” 19” 120” 148” 20” 8” 62” 114” 148”
OUTDOOR IO-152 14” - 16” 19” 120” 148” 20” 8” 62” 114” 148”
INDOOR IO-135
14” 45” 18” 18” 108” 138” 20” 11” 60” 102” 136”
INDOOR IO-150
14” 60” 21” 23” 120” 153” 25” 10” 62” 114” 153”
Notes:
1. The clearance to combustible material represents the minimum distance that must be
maintained between the outer heater surface and a nearby surface. The stated clearance
to combustibles represents a surface temperature of: Indoor = 90F° (50C°) above room
temperature; Outdoor = 117F° (65C°) above ambient temperature.
2. It is the installer’s responsibility to ensure that building materials with a low heat tolerance
which may degrade at lower temperatures are protected to prevent degradation. Examples
of low heat tolerance materials include awnings, vinyl siding, fabrics, some plastics, filmy
materials, etc.
Do not store or place anything directly under heater