IO-100 Series Submittal Data

IO-100 SUBMITTAL
SD061213
RL: 3
RD: nov2016
3
DIMENSIONS / SPECIFICATIONS IO-100 SERIES
End View
Front Perspective View
JOB
QTY
MODEL
NO.
INPUT
BTUH
GAS
FINISH 1/2” GAS INLET PIPE SIZE
MANIFOLD
PRESSURE
ELECT-
RICAL
WEIGHT
(LBS.)
HIGH
TEMP.
BLACK
MARINE
STAIN-
LESS
MINIMUM
GAS LINE
PRESSURE
MAXIMUM
GAS LINE
PRESSURE
IO-135-N 35,000 NAT 6” W.C. 14” W.C. 5” W.C.
VOLT-
AGE
24VAC
CUR-
RENT
AMPS
40VA*
32
IO-135-L 35,000 LP 11” W.C. 14” W.C. 10” W.C. 32
IO-150-N 50,000 NAT 6” W.C. 14” W.C. 5” W.C. 44
IO-150-L 50,000 LP 11” W.C. 14” W.C. 10” W.C. 44
IO-152-N
50,000/
36,500
NAT 6” W.C. 14” W.C. 5” W.C. 44
* Transformer required for a multiple heater installation:
 The first heater requires 40 VA and each additional heater 20 VA
 The sum total will be the required rating of the system or zone Transformer
 If total VA required is between transformer rating sizes, select the next higher VA rated transform-
er.
11.75”
44”
10.5”
APPROVALS:
The IO-100 Series heater has been tested and approved by CSA International:
 For Outdoor Use: ANSI Z83.26-CSA 2.37 Gas-fired Outdoor Infrared Patio Heaters
 For Indoor Use: ANSI Z83 19b-CSA 2 35b Gas-fired High-Intensity Infrared Heaters