IO-100 Series Installation/Owners Manual
2100 / IO 100 Manual
IM110107
RD: NOV 2016
R.L. 8
8
Table 2: SUGGESTED MOUNTING DISTANCES FOR COMFORT
MOUNTING PARAMETERS ***
MODEL
2135 (-SS) / IO-135 (-SS)
35,000 Btuh
MODEL
2150 / 2152 (-SS)
IO-150 / IO-152 (-SS)
50,000 Btuh
A - Mounting angle
Horizontal
30
0
Horizontal
30
0
H - Suggested height above deck
9’ 6” 9’ 0” 10’ 6” 10’ 0”
S - Side distance to patio edge
4’ 0” 4’ 0” 5’ 0” 5’ 0”
Y - Side distance between heaters
8’ 0” 8’ 0” 10’ 0” 10’ 0”
W - Distance effective coverage
7’ 0” 8’ 0” 8’ 0” 10’ 0”
Z - Front distance between heaters
14’ 0” 16’ 0” 15’ 0” 18’ 0”
*** Note: Mounting
angles and distances
are suggested to en-
sure comfort, and are
subject to site and
design conditions.
If in doubt, please
contact your
Schwank / InfraSave
distributor.
Ensure mounting
height in any location
is sufficient to prevent
patio patrons from
coming in contact
with the heater
Figure 2: MOUNTING PARAMETER DISTANCES
S Y
Z
H
A
W