Submittal
AP-SECX-CX-02A
IL-X SD
RL: 2A
RD: May 2006
KH
DIAGRAMS AND SPECIFICATIONS:
DIMENSION DIAGRAM FOR THE LUMINOUS HEATERS
Page 1
NATURAL
GAS
MINIMUM LINE PRESSURE
MAXIMUM LINE PRESSURE
MANIFOLD PRESSURE
6” w.c.
14” w.c.
5” w.c.
1/2” GAS INLET PIPE SIZE
PROPANE
GAS
MINIMUM LINE PRESSURE
MAXIMUM LINE PRESSURE
MANIFOLD PRESSURE
11” w.c.
14” w.c.
10” w.c.
1/2” GAS INLET PIPE SIZE
GAS SUPPLY
MODEL & SIZE
CONFIGURATION
VOLTAGE CURRENT CAPACITY:
BTU/HR INPUT
TOTAL WEIGHT
IN LBS.
IL 25
IL 37
IL 50
IL 75
IL 100
24 VAC
0.55 AMPS
21, 500
34, 000
50, 000
75, 000
100, 000
22
18
24
29
35
TABLE 1: DIMENSIONS :
MODEL N0. RATING BTU/
HR
WEIGHT
LBS.
IL 25
IL 37
IL 50
IL 75
IL 100
21,500
34,000
50,000
75,000
100,000
22
26
31
38
45
A B C
12 5/8”
19 3/4"
27 1/8"
38"
52 3/4"
22 3/4”
30 1/2”
38 3/8”
49 15/16”
63 3/4”
14”
18 1/4”
25 1/2”
36 3/8”
51”
B
* BTU Inputs: IL-X 37 NG - 34,000 & IL-X 37 LP - 33,000
* BTU Inputs: IL-X 37 NG - 34,000 & IL-X 37 LP - 33,000