Operation Manual

RS-232C Communication / Network command table (continued)
28
(continued on next page)
Function Command RW Min Max Default Step
Auto Power Off
(0-99 minutes)
AOT RW 0 99 0 1
Shutter Timer
1: 1 hr
3: 3 hr
6: 6 hr
SHT RW 1 6 1
USB Type B
0: Mouse
1: USB Display
USB RW 0 1 1
Lamp Time LMP R 0 999999 n/a
Lamp Time Reset
1: Reset
LRT W 0 1 n/a
Filter Time FLT R 0 999999 n/a
Filter Time Reset
1: Reset
FRT W 0 1 n/a
Source Skip USB Type A
1: Skip
0: Normal
SS3 RW 0 1 0
Source Skip USB Type B
1: Skip
0: Normal
SS4 RW 0 1 0
Source Skip HDMI 1
1: Skip
0: Normal
SS5 RW 0 1 0
Source Skip HDMI 2
1: Skip
0: Normal
SS9 RW 0 1 0
Source Skip Component
1: Skip
0: Normal
SS6 RW 0 1 0
Source Skip S-video
1: Skip
0: Normal
SS7 RW 0 1 0
Source Skip Video
1: Skip
0: Normal
SS8 RW 0 1 0
Auto Search
0: Off
1: On
ASC RW 0 1 0
Auto Keystone
0: Off
1: On
AVE RW 0 1 0
Direct Power On
0: Off
1: On
APO RW 0 1 0
[X]: supported by IN5132 and IN5142.
[WX]: supported by IN5134 and IN5144.
[WU]: supported by IN5135 and IN5145.