Operation Manual
RS-232C Communication / Network command table (continued)
23
(continued on next page)
Function Command RW Min Max Default Step
Perfect Fit Top Right corner -H CN3 RW
0
[X]: 511
[WX]: 639
[WU]: 959
0 1
Perfect Fit Top Right corner -V CN4 RW
0
[X], [WX]:
550
[WU]: 570
0 1
Perfect Fit Bottom Left corner -H CN5 RW
0
[X]: 511
[WX]: 639
[WU]: 959
0 1
Perfect Fit Bottom Left corner -V CN6 RW
0
[X], [WX]:
550
[WU]: 570
0 1
Perfect Fit Bottom Right corner -H CN7 RW
0
[X]: 511
[WX]: 639
[WU]: 959
0 1
Perfect Fit Bottom Right corner -V CN8 RW
0
[X], [WX]:
550
[WU]: 570
0 1
Perfect Fit All Corners Reset
1: Execute
CNR W
0
1 n/a
Perfect Fit Left Side Distortion
SC1 RW
98
158 128 1
Perfect Fit Right Side Distortion SC2 RW
98
158 128 1
Perfect Fit Distortion V Position SC3 RW
0
[X]: 768
[WX]: 800
[WX]: 384
[WX]: 400
1
Perfect Fit Top Side Distortion SC4 RW
98
158 128 1
Perfect Fit Bottom Side Distortion SC5 RW
98
158 128 1
Perfect Fit H Distortion Position SC6 RW
0
[X]: 1024
[WX]: 1280
[WX]: 512
[WX]: 640
1
Perfect Fit All Reset
1: Execute
SCR W
0
1 n/a
Perfect Fit Memory 1
0: Load
1: Save
CS1 W
0
1 n/a
Perfect Fit Memory 2
0: Load
1: Save
CS2 W
0
1 n/a
Perfect Fit Memory 3
0: Load
1: Save
CS3 W
0
1 n/a
Auto Eco Mode
0: Off
1: On
AEM RW
0
1 0
Eco Mode
0: Normal
1: Eco
LPE RW
0
1 0
Installation
0: Front/Desktop
1: Rear/Desktop
2: Rear/Ceiling
3: Front/Ceiling
IST RW
0
3 0