Monster Truck Owner Manual
4.)  Appearance, external cracks, discoloration, leakage. When measured capacitance 
of he capacitor has reduced below 85% of the rating, change the capacitor. 
Figure 2    Time Replacement Chart 
6-2 Relays 
To prevent a contact fault, etc., relays must be changed according to the number of accumulative switching 
times (switching life is approximately 30,000 rides). 
6-3  Projector  Bulb 
To prevent an excessive down time, due to the projector bulb burning out, obtain a spare bulb whenever the 
INFOCUS run time states over 750 hours. We do not know at this time how long this bulb lasts. This is 
only a suggestion for having on hand this spare part, not a requirement. 
Note: Projector bulbs can be obtained from Infocus direct by ordering from a local distributor or going on 
the internet to ( WWW.INFOCUS.COM
). Also the projector is warranted by Infocus direct by a pass 
through warranty. Any maintenance done to the projector will void the warranty. Should you require a 
loaner, Infocus will overnight delivery you a loaner for a fee if given a major credit card. 
6-4 NONDESTRUCTIVE TEST LIQUID PENETRANT METHOD 
•  Remove all paint a minimum of one inch of the weld area. 
•  Clean area with solvent and allow to dry. 
•  Apply penetrant to test area allowing ample time to seep into openings. 
•  Remove penetrant remaining on surface without removing the penetrant from openings. 
•  Apply developer. 
•  Visually examine the weld for penetrant indications in the developer coating. 
•  Once again clean the tested area of developer and any traces of penetrant. 
Part Name
Cooling Fan
Smoothing Capacitor Main Ckt. 
Smoothing Capacitor Control Brd. 
Standard Replacement Interval 
2to3Years
5 Years
5 Years
Description
Change as Required 
Change as Required 
Change the board as requd. 
Change as Required 
Re
lays
-------------------