CML25 Thermal Imaging Attachment User Manual V5.0 IRay Technology Co., Ltd.
Contents 1. Description...................................................................................................................... 3 2. Components and Controls ............................................................................................ 3 3. Specifications ................................................................................................................. 4 4. Function ....................................................................................................
1. Description The CML25 is a dual-use camera as a professional monocular or as an attachment for any type of the standard day scope. NO ZEROING is needed just CLAMP&SHOOT. Expand your detection ability together with your day-scope. 2. Components and Controls Fig. 2.
3. Specifications Model CML25 Detector Parameters Resolution 384x288 Pixel Size 17um NETD ≤50mk Frame Rate 50Hz Optics Parameters Objective Lens 25mm Field of View 14.9°×11.2° Diopter Adjustment -5D~+5D Detection Range 916m (Target size:1.7m×1.2m, P(n)=99%) Display Type OLED Resolution 1024×768 Electrical Parameters Battery 16340/16650 16340(1200mAh)-up to 2hr Max.
4. Function 4.1 Switch on The CML25 will be switched on after pressing the encoder for 3 seconds, and start up logo on the display screen at the same time. 4.2 Switch off The CML25 will be switched off by long pressing the encoder until the display is off. 4.3 Standby In the normal display mode, enter/exit the standby mode with right rotating the encoder. 4.4 Shutter calibration In the normal display mode, rotate the encoder to the left to perform the shutter correction. 4.
● Sharpness: 1~4 sharpness level. 4.6 Advanced menu In the normal display mode, long press the rotary encoder for 2 seconds to enter the advanced menu. There are 8 operations as shown in figure 4-2. From top to bottom the options are Ultraclear mode, Bluetooth, Video out, Zeroing type, Battery type, Image calibration, Blind pixel correction, Factory reset. If there is no operation within 5 seconds, it will exit the menu automatically. Or it will exit after long pressing the encoder for 2 seconds. Fig.
otherwise, the bluetooth will be automatically turned off ). The icon Video Transfer the analog video in pal On/Off Output displays on through the Type-C data cable. the status bar. The icon Zeroing Up to 4 groups of image calibration G1/G2/G3/G4 Type displays on data can be saved. the status bar. 3.7v is selected for rechargeable Battery 3V/3.7V batteries, and 3V is for normal dry —— Type batteries. Image Ensure the Image calibration position Refer to 4.7 interface (fig.
Please select the zeroing type before calibration referring to table 4-1 for details. In normal display mode, press option image calibration to enter the image calibration interface (fig. 4-3). Short press the encoder to switch the orientation of X-axis (left-right) and Y-axis (up-down). Rotating the encoder to change the position of screen and fast rotation to start quick shift. After completing calibration, long press the encoder to save and exit the calibration interface. Fig.
corrected blind pixel is shown on the status bar at the bottom of the screen. After the correction is completed, long press the encoder to exit the blind pixel correction. Fig. 4-4 Blind pixel correction interface 4.9 Compass Calibration Long press the encoder to enter advanced menu. Under the advanced menu, rotate CML25 360 ° 3 laps around the optical axis to enter the compass calibration interface, rotate direction as shown in fig. 4-5. Fig.
Fig. 4-6 Compass calibration interface 5. Preventative Maintenance 5.1 Battery Installation The battery power icon is displayed on the status bar ( )and there are five levels of power. When the icon is appeared on the status bar, please change the battery in time so as not to affect the use. It is necessary to power off before replacing the batteries. Because of the great design, there are many choices of the battery, such as 16340.
Fig. 5-1 Schematic diagram of battery installation 5.2 Product Cleaning and Maintenance It is prohibited to clean the product body with the cleaning product which is corroded or scratched to optical glass. The product body can be scrubbed with soft cloth dipping certain amount of alcohol. For optical glass devices such as eyepiece lens and objective lens, dust should be blown first, and then use charcoal pen or fat-free cotton dipping non-methylated alcohol to wipe slightly. 5.
6. General Trouble Shooting Table 6-1 CML25 general trouble shooting Trouble Probable Cause Solution Adjust the focal length of The focal length of the objective objective lens until the image lens does not meet. becomes clear. Image blurring No image correction for a long Perform image correction. time. Blurred vision Eye relief doesn’t match. Adjust the Eye relief until the image becomes clear. Analog video doesn’t open. Open analog video output.
7. Appendix 7.1 User Interface Description Custom interface and data cable are adopted to support Type-C power supply, serial port and PAL video; Support Type-C and battery power supply, support over-voltage and under-voltage reverse connection protection. FCC Caution. § 15.19 Labeling requirements. This device complies with part 15 of the FCC Rules.
-Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The de vice can be used in portable exposure condition without restriction.