® Universal Infinity Drain INSTALLATION VIDEOS ONLINE youtube.
1 A INSTALLATION INSTRUCTIONS (Instalación) ® B A 3 24" 1 4" Series Components: 1 2" S-DG 38 Series S-AG 65 Series A 3836 36″ Stainless Steel Grate B D 3848 48″ Stainless Steel Grate 16 A 6536 36″ Stainless Steel Grate A 3848 48″ Stainless Steel Grate D 3860 60″ Stainless Steel Grate A 6548 48″ Stainless Steel Grate 1 A 3860 60″ Stainless Steel Grate G 3848 48″ PVC Channel 1 A 6560 60″5Stainless Steel Grate " G 3836 36″ PVC Channel G 3860 60″ PVC Channel 1 G 3848 48″ PVC Channel G 6536 S
INSTALLATION INSTRUCTIONS (Instalación) Waterproofing Waterproofing technique will determine how you will install the linear drain. If using a traditional type of waterproofing, the professional will typically build a shower pan (wet waterproofed area) with PVC, Vinyl, or Noble Chlo material, follow the instructions shown on pages 4 to 7. If using a bonded type of waterproofing such as liquid membrane or fabric sheet, follow the instructions shown on pages 8 to 11.
Features ▪ Pre-pitched channel available in ABS or PVC ▪ B and removable decorative grate 18 Gauge 304L clamping collar ▪ ▪ ▪ INSTALLATION INSTRUCTIONS (Instalación) Compatible with Traditional OR Contemporary Waterproofing ▫ ▫ ▪ Traditional Waterproofing: PVC Liner, Rubber Liner, or Fiberglass Contemporary Waterproofing: liquid applied or fabric membrane USQ - Details Two clamping collar heights available (1/2” or 1”) Clamping collar can be used facing up or down TRADITIONAL WATERPROOFING Flow r
INSTALLATION INSTRUCTIONS (Instalación) 1 TRADITIONAL WATERPROOFING LOCATE THE OUTLET Establish the intended position for the linear drain by measuring the desired space and marking the center location for the drain outlet on the subfloor. Make a hole at the marked location through or into the subfloor for the drain outlet using a 3-1/2 inch hole saw. This drain can be connected to a 2 inch or 3 inch nominal pipe. A 2” pipe will fit inside of the outlet. A 3” pipe will fit over the outlet.
INSTALLATION INSTRUCTIONS (Instalación) 5 TRADITIONAL WATERPROOFING REMOVE CLAMPING COLLAR Remove the stainless steel clamping collar by unscrewing each screw and set aside. Retire el anillo de sujeción de acero inoxidable destornillando cada uno de los tornillos y déjelo a un lado. 6 APPLY WATERPROOFING Apply an appropriate construction adhesive across the mortar bed and drain channel and lay the waterproofing membrane over this adhesive. Ensure each corner is folded in each corner, without cuts.
INSTALLATION INSTRUCTIONS (Instalación) 10 TRADITIONAL WATERPROOFING INSTALL BACKERBOARD Install backerboard directly to the framing and over the waterproofing membrane that runs up the wall and. Ensure the backerboard does NOT make contact with the mortar bed on the shower floor. Be sure not to place any screws below the line at which waterproofing membrane ends on the framing.
F - Primary Mortar Bed G - Waterproofing Membrane E H - Secondary Mortar Bed B I - Thinset INSTALLATION INSTRUCTIONS (Instalación) J - Tile/Stone LIQUID/FABRIC WATERPROOFING G C H J I ® A USQ - Details F Installation with Contemporary Waterprooofing UTIF Series A - UC 65 Universal Channel B - QA 65 Decorative1 Grate Universal Infinity Drain™ C - CC Clamping Collar (1/2” or 1” High) B D - Backerboard ▪ ▪ ▪ ▪ ▪ ▪ ▪ ▪ UTIF D 24 - 24” Complete Kit UTIF 30 - 30” Complete Kit UTIF 32 - 32” C
INSTALLATION INSTRUCTIONS (Instalación) 1 LIQUID/FABRIC WATERPROOFING LOCATE THE OUTLET Establish the intended position for the linear drain by measuring the desired space and marking the center location for the drain outlet on the subfloor. Make a hole at the marked location through or into the subfloor for the drain outlet using a 3-1/2 inch hole saw. This drain can be connected to a 2 inch or 3 inch nominal pipe. A 2” pipe will fit inside of the outlet. A 3” pipe will fit over the outlet.
INSTALLATION INSTRUCTIONS (Instalación) 5 LIQUID/FABRIC WATERPROOFING REMOVE CLAMPING COLLAR Remove the stainless steel clamping collar by unscrewing each screw and set aside. Retire el anillo de sujeción de acero inoxidable destornillando cada uno de los tornillos y déjelo a un lado. 6 INSTALL BACKERBOARD Install backerboard directly to the framing and ensure that the backer board makes contact with the primary mortar bed floor.
INSTALLATION INSTRUCTIONS (Instalación) 8 LIQUID/FABRIC WATERPROOFING REATTACH CLAMPING COLLAR Screw on the clamping collar to the linear drain channel using the #1032. Do not over tighten. If using a fabric waterproofing, cut out the waterproofing membrane that is over the inside of the drain channel using a utility knife. Atornille el anillo de sujeción al canal de desagüe lineal con el #10-32. No lo apriete demasiado.
MADE IN THE USA 145 Dixon Avenue, Amityville, New York 11701 Phone 516.767.6786 ~ Fax 516.740.3066 www.infinitydrain.com INSTALLATION VIDEOS ONLINE youtube.com/IDInfinityDrain SCAN TO WATCH PRODUCT INFORMATION See infinitydrain.com for the most up-to-date product information. INFINITY DRAIN facebook.com/InfinityDrain youtube.com/IDInfinityDrain pinterest.