User's Manual

Modem configuration
Technical User Manual
InfiLINK XG CLI commands
14
xg [-grids-carrier-ix=<grids-carrier-ix>] [-grids-band=<grids-band>] -
grids {<freq_start>[-<freq_end>[/<step>]],...}
xg [-grids-carrier-ix=<grids-carrier-ix>] [-grids-band=<grids-band>] -
grids=
xg stat [-phy] [-1]
xg stat -clear
xg capabilities
xg config
xg config -self
xg config -peer-exported
xg config -defaults
Command arguments:
Point-to-point link can be set between a Master and a Slave unit only. In order to
choose InfiLINK XG device type, use the command:
xg -type {master | slave}
Example:
xg -type master
In order to setup TDD synchronization parameters, use the command:
xg -tdd-sync-src {freerun | gnss}
- freerun - unsynchronized frame start.
- gnss - synchronization from built-in GPS/GLONASS receiver.
CAUTION
GNSS option is effective for Master unit only.
CAUTION
Before enabling gnss option make sure that built-in GNSS-receiver is configured properly.
Use gps command to configure or check the status (use values of HDOP up to 1.5)
Possibility of the frequency re-use depends on the antenna types, placement,
direction, link distances, etc.
CAUTION
Please note that the following settings must be equal for the co-located units:
All co-located units must be Masters
Downlink/uplink ratio
Air frame period
Maximal distance
Channel width