User's Manual
Table Of Contents
- FCC and IC Statement
- Getting started
- 1.1. Document structure
- 1.2. Abbreviations
- 1.3. Document marks
- System Description
- 2.1. Introducing InfiLINK XG
- 2.2. Hardware Description
- 2.3. InfiLINK XG Specifications
- Installation
- 3.1. Installation Requirements
- 3.2. Equipment Positioning Guidelines
- 3.3. Installing the Outdoor Units
- 3.4. Installing the Indoor Unit
- Commissioning
- 4.1. Introduction
- 4.2. Step by step procedure
- Operation & Administration
- 5.1. Introduction
- 5.2. InfiLINK XG unit access
- 5.3. Status
- 5.3.1. Interface Statistics
- 5.3.2. Wireless Link Statistics
- 5.4. Antenna alignment
- 5.5. Maintenance
- 5.5.1. Firmware
- 5.5.2. Upload
- 5.5.3. Download
- 5.5.4. Bottom section of the page
- 5.6. Settings
- 5.6.1. General
- 5.6.2. Network Access
- 5.6.3. Radio
- 5.6.4. Switch
- 5.6.5. VLAN Switching
- 5.6.6. SNMP
- 5.6.7. Apply and Try buttons for the configuration
- 5.6.8. Configuring QoS
- 5.6.9. Configuring per-VLAN 802.1p priority assignment
- Troubleshooting
- 5
- 6.1. Introduction
- 6.2. The wireless link is down (it got lost)
- 6.3. No access to the local unit
- 6.4. Expected capacity is not met
- 6.5. Errors on the wireless link, throughput fluctuations
- 6.6. No data is being transferred
- 6.7. The management of the unit is lost
- 6.7.1. ERConsole recovery procedure
- 6.7.2. Restore to factory settings using ERConsole
Chapter 3 - Installation
Technical User Manual
InfiLINK XG
36
Building
grounding
circuit
LAN switch
ODU
Antenna pole
A separate grounded protection device
should be installed between the ODU
and the antenna, on each of the 2 RF
cables, in case the antenna has no DC-
short protection circuit.
STP
Cat.5e
43...56
V DC
AUX-ODU-
INJ-G
Pole grounding
RF cables
ODU Grounding clamp
Figure 20 - Grounding Connections Schematics when Using AUX-ODU-INJ-G
Figure 21 - AUX-ODU-INJ-G power connector
-
Press on these
catchers (1) when the
cable is terminated;
- Use the round cable
with diameter from
5mm to 6
mm with
conductor cross-
section from 0.5mm
to 2.5mm;
-
Cat 5e FTP cable
may be used.
3.3.7. Grounding when Using AUX-ODU-LPU-G
AUX-ODU-LPU-G is an optional accessory which may be used to serve as a line
protection unit for the ODU and for the indoor network equipment connected to the
Ethernet port of the IDU.
AUX-ODU-LPU-G should be properly grounded.