User's Manual
Table Of Contents
- FCC and IC Statement
- Getting started
- 1.1. Document structure
- 1.2. Abbreviations
- 1.3. Document marks
- System Description
- 2.1. Introducing InfiLINK XG
- 2.2. Hardware Description
- 2.3. InfiLINK XG Specifications
- Installation
- 3.1. Installation Requirements
- 3.2. Equipment Positioning Guidelines
- 3.3. Installing the Outdoor Units
- 3.4. Installing the Indoor Unit
- Commissioning
- 4.1. Introduction
- 4.2. Step by step procedure
- Operation & Administration
- 5.1. Introduction
- 5.2. InfiLINK XG unit access
- 5.3. Status
- 5.3.1. Interface Statistics
- 5.3.2. Wireless Link Statistics
- 5.4. Antenna alignment
- 5.5. Maintenance
- 5.5.1. Firmware
- 5.5.2. Upload
- 5.5.3. Download
- 5.5.4. Bottom section of the page
- 5.6. Settings
- 5.6.1. General
- 5.6.2. Network Access
- 5.6.3. Radio
- 5.6.4. Switch
- 5.6.5. VLAN Switching
- 5.6.6. SNMP
- 5.6.7. Apply and Try buttons for the configuration
- 5.6.8. Configuring QoS
- 5.6.9. Configuring per-VLAN 802.1p priority assignment
- Troubleshooting
- 5
- 6.1. Introduction
- 6.2. The wireless link is down (it got lost)
- 6.3. No access to the local unit
- 6.4. Expected capacity is not met
- 6.5. Errors on the wireless link, throughput fluctuations
- 6.6. No data is being transferred
- 6.7. The management of the unit is lost
- 6.7.1. ERConsole recovery procedure
- 6.7.2. Restore to factory settings using ERConsole
Chapter 3 - Installation
Technical User Manual
InfiLINK XG
31
9. Install (crimp) regular RJ-45 connector for ODU on the STP cable and seal it.
Do not use the shielded RJ-45 connector on this end of the cable, as it should
be attached only on the IDU end
10. Lay the STP cable (and the optical cable, if used) “from top to bottom” – from
ODU to IDU
11. Install (crimp and solder) shielded RJ-45 connector for IDU on the STP cable
12. Install ODU on the mounting bracket, connectors facing down, and tighten it
NOTE
It is very important to mount the ODU connectors facing down.
13. Connect the ODU-IDU cable to the ODU
14. Seal the ODU Ethernet connectors
15. Once the antenna and antenna pole are installed they must be properly
grounded: connected to the building lightning protection circuit. Antenna’s
position must be lower than the highest antenna pole point at least by 1 meter.
If antenna is NOT DC-shorted (see antenna technical documentation),
additional lightning arrestors must be used which are placed between ODU
and antenna and are grounded to the antenna pole grounding circuit
16. Connect the RF cables to the antenna ports, minding the polarization marks.
Twist the connectors tightly
17. Connect the RF cables to the ODU ports, after previously having touched the
RF cables’ connector case with ODU connector case
18. Seal RF connectors from both sides (ODU and antenna)
19. Connect the STP cable to IDU, after previously having touched IDU connector
case with STP cable connector case
20. Provide grounding for IDU
21. Connect Ethernet cable to IDU
22. Connect the IDU to power
23. Connect to the Device using Telnet protocol
3.3.4. InfiLINK XG - Xm
1. Unpack the equipment
2. Check items integrity
3. Determine the STP cable length that is used to connect IDU and ODU. The
total cable length between LAN (behind IDU) and ODU should not be longer