User's Manual

Table Of Contents
Chapter 3 - Installation
Technical User Manual
InfiLINK XG
29
Figure 13 - SFP Connection Step 3
Insert the split sealing
grommet (5) into the
cable gland threaded
coupling (6);
Screw
the cable gland
threaded coupling (6) into
the port and tighten it;
Tighten th
e cable gland
nut (4);
Do not apply excessive
force.
In order to disassemble SFP, disconnect the optical cable, pull the clip of the
SFP module and withdraw the SFP module from the slot.
3.3.3. InfiLINK XG - Um
1. Unpack the equipment
2. Check items integrity
3. Initial configuration is required for link establishment
4. Prepare RF cables of the required length. For 5GHz devices, the
recommended maximum RF cable length is 1meter
5. Install and seal the connectors on the RF cables
6. Important: Horizontal and Vertical polarization should match each other on