User's Manual

Table Of Contents
Chapter 2 - System Description
Technical User Manual
InfiLINK XG
12
2.2.3.2. External Lightning Protection (AUX-ODU-LPU-
G)
Figure 5 - AUX-ODU-LPU-G Front Panel
Optional indoor/outdoor Lightning Protection Unit (LPU) for InfiNet Wireless
systems designed to withstand the toughest conditions and protect the outdoor or
the indoor unit from sudden power surges induced by lightning strikes. It provides
the same level of protection as AUX-ODU-INJ-G.
Despite the fact every InfiNet Wireless unit has a built-in lightning protection, AUX-
ODU-LPU-G, thanks to its superior GR-1089-grade protection, greatly reduces the
risk of replacing damaged devices operating in harsh environments or difficult-to-
reach locations.
Parameter Description
Size and Weight
34x94x121 mm, 0.28 Kg
Connectors and
Interfaces
ETH IN - Ethernet input
ETH OUT - Ethernet output (protected leg)
GND - ground clamp
Supported
Ethernet Modes
10/100/1000 Mbps (Gigabit Ethernet pass-through)
Water and Dust
Protection
IP66 and IP67