User's Manual
Table Of Contents
- FCC and IC Statement
- Getting started
- 1.1. Document structure
- 1.2. Abbreviations
- 1.3. Document marks
- System Description
- 2.1. Introducing InfiLINK XG
- 2.2. Hardware Description
- 2.3. InfiLINK XG Specifications
- Installation
- 3.1. Installation Requirements
- 3.2. Equipment Positioning Guidelines
- 3.3. Installing the Outdoor Units
- 3.4. Installing the Indoor Unit
- Commissioning
- 4.1. Introduction
- 4.2. Step by step procedure
- Operation & Administration
- 5.1. Introduction
- 5.2. InfiLINK XG unit access
- 5.3. Status
- 5.3.1. Interface Statistics
- 5.3.2. Wireless Link Statistics
- 5.4. Antenna alignment
- 5.5. Maintenance
- 5.5.1. Firmware
- 5.5.2. Upload
- 5.5.3. Download
- 5.5.4. Bottom section of the page
- 5.6. Settings
- 5.6.1. General
- 5.6.2. Network Access
- 5.6.3. Radio
- 5.6.4. Switch
- 5.6.5. VLAN Switching
- 5.6.6. SNMP
- 5.6.7. Apply and Try buttons for the configuration
- 5.6.8. Configuring QoS
- 5.6.9. Configuring per-VLAN 802.1p priority assignment
- Troubleshooting
- 5
- 6.1. Introduction
- 6.2. The wireless link is down (it got lost)
- 6.3. No access to the local unit
- 6.4. Expected capacity is not met
- 6.5. Errors on the wireless link, throughput fluctuations
- 6.6. No data is being transferred
- 6.7. The management of the unit is lost
- 6.7.1. ERConsole recovery procedure
- 6.7.2. Restore to factory settings using ERConsole
Chapter 2 - System Description
Technical User Manual
InfiLINK XG
11
Parameter Description
ETH OUT - Ethernet output (data+VDC, protected leg)
PWR - DC Input
GND - Ground clamp
Supported
Ethernet Modes
10/100/1000 Mbps (Gigabit Ethernet pass-through)
Water and Dust
Protection
IP66 and IP67
DC Range
±43...±56 VDC
Ethernet
Connectors Pin-
out
ETH IN:
Pin
Description
1
Data pair A+
2
Data pair A-
3
Data pair B+
4
Data pair B-
5
Data pair C+
6
Data pair C-
7
Data pair D+
8
Data pair D-
ETH OUT:
Pin
Description
1
Data pair A+
2
Data pair A-
3
Data pair B+
4
+VDC + Data pair B-
5
+VDC + Data pair C+
6
Data pair C-
7
-VDC + Data pair D+
8
-VDC + Data pair D-
Lightning
Protection
In compliance with:
- GR-1089
- IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
- IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
- IEC 61000-4-5 (Lightning) L5, 95A (tp = 8/20us)
- ETSI ETS 300 386
Table 4 - AUX-ODU-INJ-G Specifications