Datasheet

PROFET
®
BTS 6163 D
Data Sheet 6 of 18 Rev. 1.0, 2007-07-23
Values Parameter and Conditions
at T
j
= 25, V
bb
= 24 V unless otherwise specified
Symbol
min. typ. max.
Unit
Diagnostic Characteristics
Current sense ratio, static on-condition
k
ILIS
= I
L
: I
IS,
I
IS
< I
IS,lim
16)
,
V
IS
<V
OUT
-
5 V, V
bIN
> 4.5 V
k
ILIS
--
9000 --
IL = 30A, Tj = -40°C:
Tj = +25°C:
Tj = +150°C:
IL = 7.5A, Tj = -40°C:
Tj = +25°C:
Tj = +150°C:
IL = 2.5A, Tj = -40°C:
Tj = +25°C:
Tj = +150°C:
IL = 0.5A, Tj = -40°C:
Tj = +25°C:
Tj = +150°C:
8300
8200
8100
8200
8100
8000
7200
7500
7700
5000
6000
7500
9000
9000
8800
8900
8900
8700
8900
8900
8700
9500
10000
10500
10000
9800
9500
10000
9800
9500
11000
10600
10000
16000
15000
13000
I
IN
= 0 (e.g. during deenergizing of inductive loads):
-- 0 --
Sense current under fault conditions
17)
V
ON
>1V, typ T
j
= -40...+150°C:
I
IS,fault
4.0
5.2 7.5 mA
Sense current saturation
V
ON
<1V, typ T
j
= -40...+150°C:
I
IS,lim
4.0
6.0 7.5 mA
Fault-Sense signal delay after input current positive
slope, V
ON
>1V, T
j
= -40...+150°C
t
delay(fault)
350 650 1200
µs
Current sense leakage current, I
IN
= 0 I
IS(LL)
-- 0.1 0.5
µA
Current sense offset current, V
IN
= 0, I
L
0
I
IS(LH)
-- 1.0 2.0
µA
Current sense settling time to I
IS static
after input
current positive slope,
18)
I
L
= 0 20 A, T
j
= -40...+150°C
t
son(IS)
--
250 500
µs
Current sense settling time during on condition,
18)
I
L
= 10 20 A, T
j
= -40...+150°C
t
slc(IS)
--
50 100
µs
Overvoltage protection
I
bb
= 15 mA T
j
= -40...+150°C:
V
Z,IS
68
73 -- V
16)
See also figures 4.x and 6.x on page 13 and 14.
17)
Fault conditions are overload during on (i.e. V
ON
>1V typ.), overtemperature and short circuit; see also truth
table on page 8.
18)
Not subject to production test, specified by design.