Datasheet
7 Oct-21-1997
BSM 75 GB 120 DN2
Typ. switching time
I = f (I
C
) , inductive load , T
j
= 125°C
par.: V
CE
= 600 V, V
GE
= ± 15V, R
G
= 15
Ω
0 20 40 60 80 100 120 140 A 180
I
C
1
10
2
10
3
10
4
10
ns
t
tdon
tr
tdoff
tf
Typ. switching time
t = f (R
G
) , inductive load ,
T
j
= 125°C
par.: V
CE
= 600V, I
C
= 75 A
0 10 20 30 40 50 60
Ω
80
R
G
1
10
2
10
3
10
4
10
ns
t
tdon
tr
tdoff
tf
Typ. switching losses
E = f (I
C
) ,
inductive load ,
T
j
= 125°C
par.: V
CE
= 600 V, V
GE
= ± 15 V, R
G
= 15 Ω
0 20 40 60 80 100 120 140 A 180
I
C
0
5
10
15
20
25
30
mWs
40
E
Eon
Eoff
Typ. switching losses
E = f (R
G
) , inductive load , T
j
= 125°C
par.: V
CE
= 600 V, V
GE
= ± 15 V, I
C
= 75 A
0 10 20 30 40 50 60
Ω
80
R
G
0
5
10
15
20
mWs
30
E
Eon
Eoff