Datasheet
Data Sheet 7 V1.5, 2012-08-17
TLE 8102 SG
Smart Dual Channel Powertrain Switch
Maximum Ratings and Operating Conditions
4 Maximum Ratings and Operating Conditions
4.1 Absolute Maximum Ratings
T
j
= -40 ⋅C to +150 ⋅C; all voltages with respect to ground, positive current flowing into pin
(unless otherwise specified)
Pos. Parameter Symbol Limit Values Unit Conditions
Min. Max.
Supply Voltage
V
DD
-0.3 7 V –
Continuous Drain Source Voltage
(OUT1 to OUT2)
V
DS
-0.3 48 V –
Input Voltage, All Inputs and Data
o
utputs, Sense Lines
V
IN
-0.3 7 V –
Output Current per Channel
2)
2) Output current rating as long as maximum junction temperature is not exceeded. The maximum output current in the
application has to be calculated using
R
thJA
depending onmounting conditions.
I
D
-3 I
D(lim1,2) min.
A Output ON
Maximum Voltage for short circuit
Pr
otection (single event)
3)
3) Device mounted on PCB (50 mm × 50 mm × 1.5 mm epoxy, FR4) with 6 cm
2
copper heatsink area (one layer, 70 μm thick);
PCB in test chamber with blown air.
V
SC, single
– 48 V Current Limit 2, slew
rate 1 (default setting)
– 32 V Current Limit 2,
slew rate 2
– 18 V Current Limit 1,
slew rate 1 or 2
Elec
trostatic Discharge Voltage
(human body model) according to
EIA/JESD22-A114-E
V
ESD
-4000
-2000
4000
2000
V
V
Output Pins
All other Pins
DIN Humidity Category, DIN 40 040 E –
IEC Climatic Category, DIN IEC 68-1 40/150/ 56 –
Note: Stresses above the ones listed here may cause perman
ent damage to the device. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Note: Integrated protection functions are designed to prevent IC de
struction under fault conditions described in the
data sheet. Fault conditions are considered as “outside” normal operating range. Protection functions are
not designed for continuous repetitive operation.
Absolute Maximum Ratings
1)
1) Not subject to production test, specified by design.
4.1.1
4.1.2
4.1.3
4.1.4
4.1.5
4.1.6
4.1.7
4.1.8