Datasheet

Data Sheet 6 Rev. 1.6, 2008-01-22
TLE 7469
Note: Maximum ratings are absolute ratings; exceeding any one of these values may
cause irreversible damage to the integrated circuit. Integrated protection functions
are designed to prevent IC destruction under fault conditions. Fault conditions are
considered as outside normal operating range. Protections functions are not
designed for continuous repetitive operation.
Watchdog Input WDI
Voltage
V
WDI
-0.3 5.5 V Permanent
Voltage
V
WDI
-0.3 6.2 V t < 10 s
1)
Current I
WDI
mA internally limited
Sense Input SI
Voltage
V
SI
-0.3 45 V Observe current limit
I
SImax
2)
Current I
SI
-1 1 mA
Sense Output SO
Voltage
V
SO
-0.3 5.5 V Permanent
Voltage
V
SO
-0.3 6.2 V t < 10 s
1)
Current I
SO
mA internally limited
Temperatures
Junction temperature
T
j
–150°C–
Storage temperature
T
stg
-50 150 °C–
1) Exposure to these absolute maximum ratings for extended periods (t > 10 s) may affect device reliability.
2) External resistor required to keep current below absolute maximum rating when voltages 5.5 V are applied.
Table 2 Absolute Maximum Ratings (cont’d)
-40 °C <
T
j
< 150 °C
Parameter Symbol Limit Values Unit Remarks
Min. Max.