Datasheet

Data Sheet 15 Rev. 1.0, 2009-06-01
TLE7276-2
Electrical Characteristics
5.3 Electrical Characteristics Enable Function
The Enable Function allows disabling/enabling the regulator via the input pin EN. The regulator is turned on in
case the pin EN is connected to a voltage higher than VEN,H. This can be e.g. the battery voltage, whereby no
additional pull-up resistor is needed. The regulator can be turned off by connecting the pin EN to a voltage less
than VEN,L, e.g. GND.
5.4 Typical Performance Characteristics Enable Function
Electrical Characteristics Enable
V
I
=13.5 V; T
j
= -40 °C to 150 °C; all voltages with respect to ground, positive current flowing into pin
(unless otherwise specified)
Pos. Parameter Symbol Limit Values Unit Measuring Condition
Min. Typ. Max.
5.3.13 High Level Input Voltage
V
EN,H
3.1––V V
Q
4.9 V
5.3.14 Low Level Input Voltage
V
EN,L
––0.8V V
Q
0.3 V
5.3.15 High Level Input Current
I
EN,H
–34µAV
EN
= 5 V
Enabled Input Current
I
EN
versus
Input Voltage
V
I
, EN=Off
Enabled Input Current
I
EN
versus
Enabled Input Voltage
V
EN
I
EN
[µA]
25_IINH vs VIN INH_off.vsd
0.6
0.4
0.2
0.8
T
j
= 25°C
10
V
IN
[V]
30 40
20
1.0
T
j
= -40°C
T
j
= 150°C
EN = OFF
I
EN
[µA]
24_IINH vs VINH.vsd
30
20
10
40
T
j
= 25°C
10
V
EN
[V]
30 40
20
50
T
j
= -40°C
T
j
= 150°C