Datasheet

B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0
Channel
Fault Typing
Current Source
MOSI CH10 XXXXXXXFTSR1SR0SW2SW1SW0
MISO CH 1 0 OL/SG VSHT OTMP 0 0 0 REF FT SR1 SR0 SW2 SW1 SW0
Channel
Open Load or
Short to GND
Short to Vpwr
Over
Temperature
Ext./Int.
Reference Volt.
Fault Typing
Current Source
Switching
Hysteresis
Slew RateSlew Rate
General
Configuration
General
Configuration
Switching
Hysteresis
TLE 7241E
Functional Description and Electrical Characteristics
Data Sheet 63 Rev. 1.1, 2009-01-19
Figure 28 General Configuration Register
MOSI
B12 - B6: Not used, Ignored - Don’t Care
B5 Fault Typing Bit: Activates a 40 μA pull-up current on POSx pin for SG/OL
differentiation. Default = 0 (disabled)
B4 - B3 Slew Rate: Setting for the slew rate (see Table 5). Default = 3 (1.2 V/μs)
B2 - B0 Switching Hysteresis: Setting for the hysteresis value (see Table 6),
Default = 0 (40 mVpp)
MISO
B12 OL/SG: Open Load / Short to Ground fault flag
B11 VSHT: Short to BAT (Shorted Load) fault flag
B10 OTMP: Overtemperature fault flag
B9 - B7: Not used, always 0
B6 REF: = 0 when an external reference is detected on the REF pin,
B6 REF: = 1 when the REF pin is grounded and the internal 2.5 V reference is active
B5 FT: Contents of the FT-bit in the general configuration register
B4 - B3 Slew Rate: Contents of the Slew Rate settings in the general configuration
register
B2 - B0 SW: Contents of the switching hysteresis setting in the general configuration
register