Datasheet

Data Sheet 34 Rev. 1.1, 2009-01-19
TLE 7241E
Functional Description and Electrical Characteristics
5.5.1.14
OUTx
3)5)
Switching
hysteresis
100
Sw Hyst.
register = 6
DAC counts
= ±42
dV
hyst100
88.7 99.7 109.7
mVpp
100 mV programmed
setting
Input Command >
200 mV
REF = 2.5V
5.5.1.15 OUTx
3)5)
Switching
hysteresis
110
Sw Hyst.
register = 7
DAC counts
= ±46
dV
hyst110
100.5 110.5 120.5
mVpp
110 mV programmed
setting
Input Command >
200 mV
REF = 2.5V
1) Positive current flow is into the device.
2)
T
J
= 25 °C
3) Not subject to production test, specified by design.
4) Electrical Distributions must be performed on this parameter as defined in the AEC-Q100 Specification Table 2
test 27.
5) When the internal reference is used (REF pin grounded), the minimum and maximum limits must be increased
by +/- 2%
Electrical Characteristics (cont’d)
1)
T
j
= -40 to 150 °C; V
BAT
= 9 V to 18 V; V
DD
= 4.75 V to 5.25 V
Pos. Parameter Symbol Limit Values Unit Test Conditions and
Instructions
Min. Typ.
2)
Max.