Datasheet

Data Sheet TLE 6232 GP
V2.3 Page 2009-11-18
5
Electrical Characteristics
Parameter and Conditions Symbol Values Unit
V
S
= 4.5 to 5.5 V ; T
j
= - 40 °C to + 150 °C ; Reset = H
(unless otherwise specified)
min typ max
1. Power Supply, Reset
Supply Voltage
2
V
S
4.5 -- 5.5
V
Supply Current I
S
-- -- 10 mA
Supply Current in Standby Mode (RESET = L) I
S(stdy)
-- -- 10 µA
Minimum Reset Duration t
Reset,min
1 -- -- µs
2. Power Outputs
ON Resistance V
S
= 5 V; I
D
= 1 A T
J
= 25°C
Channel 1-4 T
J
= 150°C
R
DS(ON)
--
--
0.25
--
0.28
0.5
ON Resistance V
S
= 5 V; I
D
= 500 mA T
J
= 25°C
Channel 5,6 T
J
= 150°C
R
DS(ON)
--
--
0.45
--
0.55
1
Output Clamping Voltage Output OFF V
DS(AZ)
45 53 60 V
Current Limit Channel 1-4
Current Limit Channel 5,6
I
D(lim) 1-4
I
D(lim) 5,6
3
1.5
4
2
6
3
A
Output Leakage Current V
Reset
= L
I
D(lkg)
-- -- 10 µA
Turn-On Time Ch 1-4 I
D
= 2 A, resistive load
Ch 5,6 I
D
= 1 A, resistive load
t
ON
-- 5 10 µs
Turn-Off Time Ch 1-4 I
D
= 2 A, resistive load
Ch 5,6 I
D
= 1 A, resistive load
t
OFF
-- 5 10 µs
Switch-On Slew Rate (resistive load) s
on
1 4 20 V/µs
Switch-Off Slew Rate (resistive load) s
on
1 4 20 V/µs
3. Digital Inputs
Input Low Voltage V
INL
- 0.3 -- 1.0 V
Input High Voltage V
INH
2.0 -- -- V
Input Voltage Hysteresis V
INHys
100 200 400 mV
Input Pull Down/Up Current (IN1 ... IN6) I
IN(1..6)
10 20 50 µA
Input Pull Up Current (Reset) I
IN(Res)
10 20 50 µA
Input Pull Down Current (PRG) I
IN(PRG)
10 20 50 µA
Input Pull Up Current (
CS
, SI, SCLK) I
IN(SI,SCLK)
10 20 50 µA
4. Digital Outputs (SO,
FAULT
)
SO High State Output Voltage I
SOH
= -2 mA V
SOH
V
S
- 1 -- -- V
SO Low State Output Voltage I
SOL
= 2 mA V
SOL
-- -- 0.4 V
Output Tri-state Leakage Current
CS
= H, 0 V
SO
V
S
I
SOlkg
-10 0 10 µA
FAULT Output Low Voltage I
FAULT
= 2 mA V
FAULTL
-- -- 0.4 V
2
For V
S
< 4.5V the power stages are switched according the input signals and data bits or are definitely switched
off. This under-voltage reset gets active at V
S
= 3V (typ. value) and is specified by design.