Datasheet
Datasheet TLE 6228 GP
Electrical Characteristics
Parameter and Conditions Symbol Values Unit
V
S
= 4.8 to 18 V ; T
j
= – 40 °C to + 150 °C
(unless otherwise specified)
min typ max
5. Standby Input (STBY)
Input low voltage V
STBY
0 1 V
Input high voltage V
STBY
3.5 V
S
V
Input current V
STBY
= 18 V I
STBY
300 µA
6. Diagnostic Functions
Open load detection voltage
V
ENA
= X, V
IN
= L
V
S
≥ 6.5 V V
DS(OL)
0.3*V
S
0.33*V
S
0.36*V
S
V
Open load detection current channel 1,2
V
ENA
= V
IN
= H
V
S
≥ 6.5 V I
D(OL) 1,2
100 160 250 mA
Open load detection current channel 3,4
V
ENA
= V
IN
= H
V
S
≥ 6.5 V I
D(OL) 3,4
100 160 250 mA
Overload detection current channel 1,2 V
S
≥ 6.5 V I
D(lim) 1,2
5 7.5 A
Overload detection current channel 3,4 V
S
≥ 6.5 V I
D(lim) 3,4
3 5.5 A
Overtemperature shutdown threshold
5
Hysteresis
T
th
T
hys
170
10
200 °C
K
Pulse Width for static diagnostic output t
IN
500 µs
5
This parameter will not be tested but assured by design
V4.1 Page
6
2010-07-10