Datasheet
Datasheet TLE 6228 GP
Electrical Characteristics
Parameter and Conditions Symbol Values Unit
V
S
= 4.8 to 18 V ; T
j
= - 40 °C to + 150 °C
(unless otherwise specified)
min typ max
1. Power Supply (V
S
)
Supply current (Outputs ON) I
S
8 mA
Supply current (Outputs OFF)
V
ENA
= L, V
STBY
= H
I
S
4 mA
Standby current V
STBY
= L I
S
10 µA
Operating voltage V
S
4.8 32 V
2. Power Outputs
ON state resistance Channel 1,2 T
j
= 25 ° C
I
D
= 1A; V
S
≥ 9.5 V T
j
= 150°C
R
DS(ON)
0.23 0.26
0.5
Ω
ON state resistance Channel 3,4 T
j
= 25 ° C
I
D
= 1A; V
S
≥ 9.5 V T
j
= 150°C
R
DS(ON)
0.28 0.4
0.75
Ω
Z-Diode clamping voltage (OUT1...4) I
D
≥ 100 mA V
DS(AZ)
45 60 V
Pull down current V
STBY
= H, V
IN
= L I
PD
10 20 50 µA
Output leakage current
3
V
STBY
= L, 0V ≤ V
DS
≤ 20V I
Dlk
5 µA
Output turn on time
4
I
D
= 1 A
Output turn off time
4
I
D
= 1 A
Output on fall time
4
I
D
= 1 A
Output off rise time
4
I
D
= 1 A
Overload switch-off delay time
4
Output off status delay time
4
Failure extension Time for Status Report
Input Suppression Time
Open Load (off) filtering Time
5
t
on
t
off
t
fall
t
rise
t
DSO
t
D
t
D-failure
t
D-IN
t
fOL(off)
3
3
3
3
20
500
500
500
10
15
20
10
5
60
1200
1200
1200
30
50
60
30
30
100
3000
3000
3000
100
µs
3. Digital Inputs (IN1, IN2, IN3, IN4, ENA)
Input low voltage V
INL
- 0.3 1.0 V
Input high voltage V
INH
2.0 6.0 V
Input voltage hysteresis
5
V
INHys
50 200 mV
Input pull down current V
IN
= 5 V; V
S
≥ 6.5 V I
IN
10 30 60 µA
Enable pull down current V
ENA
= 5 V; V
S
≥ 6.5 V I
ENA
10 20 40 µA
4. Digital Status Outputs (ST1 - ST4) Open Drain
Output voltage low I
ST
= 2 mA V
STL
0.5 V
Leakage current high I
STH
2 µA
3
If the output voltage exceeds 35V, this current (zener current of a internal structure) can rise up to 1mA
4
See timing diagram, resistive load condition; V
S
≥ 9 V
5
This parameter will not be testet but assured by design
V4.1 Page
5
2010-07-10