Datasheet
Data Sheet TLE 6220 GP
V2.2 Page 2009-11-18
4
Electrical Characteristics
Parameter and Conditions Symbol Values Unit
V
S
= 4.5 to 5.5 V ; T
j
= - 40 °C to + 150 °C ; Reset = H
(unless otherwise specified)
min typ max
1. Power Supply, Reset
Supply Voltage
4
V
S
4.5 -- 5.5
V
Supply Current
5
I
S
--
1 2 mA
Minimum Reset Duration
(After a reset all parallel inputs are ORed with the SPI
data bits)
t
Reset,min
10
µs
2. Power Outputs
ON Resistance V
S
= 5 V; I
D
= 1 A T
J
= 25°C
T
J
= 150°C
R
DS(ON)
--
--
0.32
--
0.4
0.7
Ω
Output Clamping Voltage output OFF V
DS(AZ)
45
53
60 V
Current Limit I
D(lim)
3 4.5 6 A
Output Leakage Current V
RESET
= L
I
D(lkg)
-- --
10 µA
Turn-On Time I
D
= 1 A, resistive load t
ON
--
5 10 µs
Turn-Off Time I
D
= 1 A, resistive load t
OFF
--
5 10 µs
3. Digital Inputs
Input Low Voltage V
INL
- 0.3
--
1.0 V
Input High Voltage V
INH
2.0
--
VS+0.3
V
Input Voltage Hysteresis V
INHys
50 100
200
mV
Input Pull Down/Up Current (IN1 ... IN4) I
IN(1..4)
20 50 100 µA
PRG,
RESET
Pull Up Current I
IN(PRG,Res)
20 50 100 µA
Input Pull Down Current (SI, SCLK) I
IN(SI,SCLK)
10 20 50 µA
Input Pull Up Current (
CS
) I
IN(CS)
10 20 50 µA
4. Digital Outputs (SO,
FAULT
)
SO High State Output Voltage I
SOH
= 2 mA V
SOH
V
S
- 0.4
-- -- V
SO Low State Output Voltage I
SOL
= 2.5 mA V
SOL
-- -- 0.4 V
Output Tri-state Leakage Current
CS
= H, 0 ≤ V
SO
≤ V
S
I
SOlkg
-10 0 10 µA
FAULT
Output Low Voltage I
FAULT
= 1.6 mA V
FAULTL
-- --
0.4 V
Current Limitation; Overload Threshold Current I
D(lim) 1...4
3 4.5 6 A
Overtemperature Shutdown Threshold
Hysteresis
6
T
th(sd)
T
hys
170
--
--
10
200
--
°C
K
4
For V
S
< 4.5V the power stages are switched according the input signals and data bits or are definitely switched
off. This undervoltage reset gets active at V
S
= 3V (typ. value) and is guaranteed by design.
5
If Reset = L the supply current is reduced to typ. 20µA
6
This parameter will not be tested but guaranteed by design