Datasheet
TLE 6209 R
Data Sheet, Version 3.1 22 2007-08-01
Note: Temperature thresholds are guaranteed by design.
Thermal Prewarning, Warning and Shutdown
Thermal prewarning
junction temperature
T
jPW
120 140 160 °C–
Temperature prewarning
hysteresis
∆
T –20 –K–
Thermal warning junction
temperature
T
jW
140 160 180 °C–
Temperature prewarning
hysteresis
∆
T –20 –K–
Thermal shutdown junction
temperature
T
jSD
160 180 200 °C–
Temperature shutdown
hysteresis
∆
T –20 –K–
Ratio of W to PW
temperature
T
jW
/
T
jPW
1.07 1.14 – – –
Ratio of SD to W
temperature
T
jSD
/
T
jW
1.06 1.13 – – –
3.3 Electrical Characteristics (cont’d)
8 V <
V
S
< 40 V; 4.75 V < V
CC
< 5.25 V; INH = High; all outputs open;
– 40 °C <
T
j
< 150 °C; unless otherwise specified
Parameter Symbol Limit Values Unit Test Conditions
min. typ. max.