Datasheet
TLE 6209 R
Data Sheet, Version 3.1 17 2007-08-01
High-Side Switch Overcurrent
High-side shutdown
threshold
I
SDH
8 1218A –
Shutdown delay time
t
dSD
15 25 40 µs–
Short circuit current
I
SC
– – 25 A during t
dSD
Note: For short circuit current definition, see Figure 5. Short circuit current is
guaranteed by design
Leakage Current / Output Current in Tristate
Source-Output-Stage
I
QLH
–120 –50 – µA V
OUT
= 0 V
Sink-Output-Stage
I
QLL
–0.51mAV
OUT
= V
S
Output Delay Times (device not in stand-by for t > 1 ms)
High-side ON t
dONH
–410µs V
S
= 13.2 V,
Resistive load of
12 Ω
High-side OFF
t
dOFFH
–0.61µs
Low-side ON
t
dONL
–23.5µs
Low-side OFF
t
dOFFL
–2.54µs
Output Switching Times
(device not in stand-by for t > 1 ms)
High-side switch rise time t
RISE H
–1.83.5µs V
S
= 13.2 V,
Resistive load of
12 Ω
High-side switch fall time
t
FALL H
–0.20.8µs
Low-side switch rise time
t
RISE L
26.511µs
Low-side switch fall time
t
FALL L
24.36.5µs
Note: For switching time definitions, see Figure 6.
3.3 Electrical Characteristics (cont’d)
8 V <
V
S
< 40 V; 4.75 V < V
CC
< 5.25 V; INH = High; all outputs open;
– 40 °C <
T
j
< 150 °C; unless otherwise specified
Parameter Symbol Limit Values Unit Test Conditions
min. typ. max.