Datasheet
TLE 4729 G
Data Sheet 8 2005-01-17
For details see next four pages.
These parameters are not 100% tested in production, but guaranteed by design.
Error Output Timing
Time Phase X to IXX
Time IXX to Phase X
Delay Phase X to Error 2
Delay Phase X to Error 1
Delay IXX to Error 2
Reset delay after Phase X
Reset delay after IXX
t
PI
t
IP
t
PEsc
t
PEol
t
IEsc
t
RP
t
RI
–
–
–
–
–
–
–
5
12
45
15
30
3
1
20
100
100
50
80
10
5
µs
µs
µs
µs
µs
µs
µs
–
Characteristics (cont’d)
V
S
= 6 to 16 V; T
j
= – 40 to 130 °C
Parameter Symbol Limit Values Unit Test Condition
min. typ. max.