Datasheet
TLE 4471
Data Sheet 5 Rev. 1.6, 2009-02-03
Table 2 Absolute Maximum Ratings
T
j
= -40 to 150 °C
Parameter Symbol Limit Values Unit Notes
Min. Max.
Input I
Input voltage V
I
-45
–
42
60
V
V
–
t < 400 ms
Main Output Q1
Output voltage
V
Q1
-0.3 7 V –
Output current
I
Q1
– – mA internally limited
Tracking Output Q2
Output voltage
V
Q2
-227V –
Output current
I
Q2
– – mA internally limited
Tracking Output Q3
Output voltage
V
Q3
-227V –
Output current
I
Q3
-5 – mA internally limited
Enable Input E1
Input voltage
V
E1
-0.3 16 V –
Input current
I
E1
-20 20 mA –
Enable Input E2
Input voltage
V
E2
-0.3 6.5 V –
Input current
I
E2
– – mA internally limited
Enable Input E3
Input voltage
V
E3
-0.3 16 V –
Input current
I
E3
-20 20 mA –
Enable Input EN
Input voltage
V
EN
-0.3 7 V –
Input current
I
EN
– – mA internally limited
Reference Output REF2
Output voltage
V
REF2
-0.3 4.5 V –
Output current
I
REF2
––mA–