Datasheet

TLE 4276
Data Sheet 7 Rev. 2.7, 2007-10-23
Table 5 Characteristics
V
I
= 13.5 V; -40 °C < T
j
< 150 °C (unless otherwise specified)
Parameter Sym-
bol
Limit Values Unit Measuring
Condition
Measuring
Circuit
Min. Typ. Max.
Output voltage
V
Q
4.8 5.0 5.2 V V50-Version
5 mA <
I
Q
< 400 mA
6 V <
V
I
< 28 V
1
Output voltage
V
Q
4.8 5.0 5.2 V V50-Version
5 mA <
I
Q
< 200 mA
6 V <
V
I
< 40 V
1
Output voltage
V
Q
8.16 8.50 8.84 V V85-Version
5 mA <
I
Q
< 400 mA
9.5 V <
V
I
< 28 V
1
Output voltage
V
Q
8.16 8.50 8.84 V V85-Version
5 mA <
I
Q
< 200 mA
9.5 V <
V
I
< 40 V
1
Output voltage
V
Q
9.6 10.0 10.4 V V10-Version
5 mA <
I
Q
< 400 mA
11 V <
V
I
< 28 V
1
Output voltage
V
Q
9.6 10.0 10.4 V V10-Version
5 mA <
I
Q
< 200 mA
11 V <
V
I
< 40 V
1
Output voltage
tolerance
V
Q
-4 4 % V-Version
R
2
< 50 k
V
Q
+ 1 V V
I
40 V
V
I
> 4.5 V
5 mA
I
Q
400 mA
1
Output current
limitation
1)
I
Q
400 600 1100 mA 1
Current
consumption;
I
q
= I
I
- I
Q
I
q
–– 10µA V
INH
= 0 V;
T
j
100 °C
1
Current
consumption;
I
q
= I
I
- I
Q
I
q
100 220 µA I
Q
= 1 mA 1
Current
consumption;
I
q
= I
I
- I
Q
I
q
–5 10mAI
Q
= 250 mA 1