Datasheet
Data Sheet 4 Rev. 2.3, 2008-03-10
TLE 4274 / 3.3V;2.5V
Note: Maximum ratings are absolute ratings; exceeding any one of these values may
cause irreversible damage to the integrated circuit.
Table 2 Absolute Maximum Ratings
T
j
= -40 to 150 °C
Parameter Symbol Limit Values Unit Test Condition
Min. Max.
Input
Voltage V
I
-42 45 V –
Current
I
I
– – – Internally limited
Output
Voltage
V
Q
-1.0 40 V –
Current
I
Q
– – – Internally limited
Ground
Current
I
GND
–100mA–
Temperature
Junction temperature
T
j
–150°C–
Storage temperature
T
stg
-50 150 °C–
Table 3 Operating Range
Parameter Symbol Limit Values Unit Remarks
Min. Max.
Input voltage
V
I
4.7 40 V –
Junction temperature
T
j
-40 150 °C–
Thermal Resistance
Junction ambient
R
thja
– 100 K/W SOT223
1)
1) Soldered in, 1 cm
2
copper area at pin 4, FR4
Junction ambient R
thja
– 70 K/W TO252
2)
2) Soldered in, minimal footprint, FR4
Junction case R
thjc
– 25 K/W SOT223
Junction case
R
thjc
–4K/WTO252