Datasheet

TLE 4268
Data Sheet 7 Rev. 1.5, 2007-03-20
Table 5 Characteristics
V
I
= 13.5 V; -40 °C T
j
125 °C (unless otherwise specified)
Parameter Symbol Limit Values Unit Test Condition
Min. Typ. Max.
Output voltage
V
Q
4.90 5.00 5.10 V 5 mA I
Q
150 mA;
6 V
V
I
28 V
Output current limiting
I
Q
180 250 mA
Current consumption
I
q
= I
I
- I
Q
I
q
300 450 µA I
Q
= 0 mA
Current consumption
I
q
= I
I
- I
Q
I
q
1320mAI
Q
= 150 mA
Drop voltage
V
DR
0.25 0.50 V I
Q
= 150 mA
1)
Load regulation V
Q,Lo
1030mVI
Q
= 5 to 150 mA
Line regulation
V
Q,Li
1030mVV
I
= 6 to 28 V
I
Q
= 150 mA
Reset Generator
Reset threshold
V
Q,rt
4.2 4.5 4.8 V
Reset adjust
threshold
V
RADJ
1.28 1.35 1.45 V
Reset low voltage
V
RO,l
0.2 0.5 V 1 mA external
Saturation voltage
V
D
30 100 mV V
Q
< V
RT
Charging current I
D,c
51218µA V
D
= 1.0 V
Upper reset timing
threshold
V
DU
1.4 1.8 2.2 V
Reset delay time
t
rd
10 15 25 ms C
D
= 100 nF
Reset reaction time
t
rr
–2–µs C
D
= 100 nF
Pull-up
R
RO
18 30 46 k with resp. to V
Q
Lower reset timing
threshold
V
DRL
0.2 0.4 0.55 V