Datasheet

Data Sheet 4 Rev. 2.8, 2008-05-19
TLE 4262
Circuit Description
The control amplifier compares a reference voltage, which is kept highly accurate by
resistance adjustment, to a voltage that is proportional to the output voltage and drives
the base of the series transistor via a buffer. Saturation control as a function of the load
current prevents any over-saturation of the power element. If the externally scaled down
output voltage at the reset threshold input drops below 1.35 V, the external reset delay
capacitor is discharged by the reset generator. If the voltage on the capacitor reaches
the lower threshold
V
DRL
, a reset signal is issued on the reset output and not cancelled
again until the upper threshold
V
DU
is exceeded. If the reset threshold input is connected
to GND, reset is triggered at an output voltage of 4.5 V. The IC can be switched at the
TTL-compatible, low-active inhibit input. It also includes a number of internal circuits for
protection against:
Overload
Overtemperature
Reverse polarity
Figure 2 Block Diagram
AEB01081
Control
Amplifier
Buffer
Reference
Bandgap
Adjustment
Protection
Circuit
Control and
Saturation
Temperature
Sensor
Reset
Generator
6
I
Q
D
RO
RADJ
3-5, 10-1214
INH GND
1
7
9
13