Datasheet

C505/C505C/C505A/C505CA
Data Sheet 59 12.00
Power Supply Currents
Notes see Page 60
Parameter Symbol Limit Values Unit Test Condition
typ.
12)
max.
13)
C505 /
C505C
Active Mode 12 MHz
20 MHz
I
DD
I
DD
19.3
31.3
27.0
39
mA
7)
Idle Mode 12 MHz
20 MHz
I
DD
I
DD
10.3
16.2
13.0
21.0
mA
8)
Active Mode with
slow-down enabled
12 MHz
20 MHz
I
DD
I
DD
3.9
4.8
5.5
7.5
mA
9)
Idle Mode with
slow-down enabled
12 MHz
20 MHz
I
DD
I
DD
3.2
4.0
5.0
7.0
mA
10)
Power down mode I
PD
10 50 µA V
DD
= 2..5.5 V
11)
C505A-4E
/C505CA-4E
Active Mode 16 MHz
20 MHz
I
DD
I
DD
28.7
35.2
30.7
37.6
mA
7)
Idle Mode 16 MHz
20 MHz
I
DD
I
DD
14.9
17.7
15.9
18.9
mA
8)
Active Mode with
slow-down enabled
16 MHz
20 MHz
I
DD
I
DD
9.9
12.3
12.8
15.6
mA
9)
Idle Mode with
slow-down enabled
16 MHz
20 MHz
I
DD
I
DD
5.1
6.3
5.6
6.8
mA
10)
Power down mode I
PD
5.6 20 µA V
DD
= 2..5.5 V
11)
C505A-4R /
C505CA-4R
/C505A-2R /
C505CA-2R
/C505A-L /
C505CA-L
Active Mode 16 MHz
20 MHz
I
DD
I
DD
22.8
27.6
29.2
35.3
mA
7)
Idle Mode 16 MHz
20 MHz
I
DD
I
DD
12.7
15.0
16.3
19.3
mA
8)
Active Mode with
slow-down enabled
16 MHz
20 MHz
I
DD
I
DD
6.6
7.3
8.2
9.3
mA
9)
Idle Mode with
slow-down enabled
16 MHz
20 MHz
I
DD
I
DD
5.0
5.3
5.9
6.5
mA
10)
Power down mode I
PD
5.3 30 µA V
DD
= 2..5.5 V
11)