Datasheet

C164CI/SI
C164CL/SL
Data Sheet 46 V2.0, 2001-05
Power Consumption C164CI (OTP)
(Operating Conditions apply)
Parameter Sym-
bol
Limit Values Unit Test
Conditions
min. max.
Power supply current (active)
with all peripherals active
I
DD
10 +
3.5 ×
f
CPU
mA RSTIN = V
IL
f
CPU
in [MHz]
1)
Idle mode supply current
with all peripherals active
I
IDX
5 +
1.25 ×
f
CPU
mA RSTIN = V
IH1
f
CPU
in [MHz]
1)
Idle mode supply current
with all peripherals deactivated,
PLL off, SDD factor = 32
I
IDO
2)
500 +
50 ×
f
OSC
µ ARSTIN = V
IH1
f
OSC
in [MHz]
1)
Sleep and Power-down mode
supply current with RTC running
I
PDR
2)
200 +
25 ×
f
OSC
µ A V
DD
= V
DDmax
f
OSC
in [MHz]
3)
Sleep and Power-down mode
supply current with RTC disabled
I
PDO
50 µA V
DD
= V
DDmax
3)
1)
The supply current is a function of the operating frequency. This dependency is illustrated in Figure 10.
These parameters are tested at
V
DDmax
and maximum CPU clock with all outputs disconnected and all inputs
at
V
IL
or V
IH
.
2)
This parameter is determined mainly by the current consumed by the oscillator (see Figure 8). This current,
however, is influenced by the external oscillator circuitry (crystal, capacitors). The values given refer to a typical
circuitry and may change in case of a not optimized external oscillator circuitry.
3)
This parameter is tested including leakage currents. All inputs (including pins configured as inputs) at 0 V to
0.1 V or at
V
DD
- 0.1 V to V
DD
, V