Datasheet

C164CI/SI
C164CL/SL
Data Sheet 43 V2.0, 2001-05
Parameter Interpretation
The parameters listed in the following partly represent the characteristics of the C164CI
and partly its demands on the system. To aid in interpreting the parameters right, when
evaluating them for a design, they are marked in column Symbol:
CC (Controller Characteristics):
The logic of the C164CI will provide signals with the respective characteristics.
SR (System Requirement):
The external system must provide signals with the respective characteristics to the
C164CI.
DC Characteristics
(Operating Conditions apply)
1)
Parameter Symbol Limit Values Unit Test Conditions
min. max.
Input low voltage (TTL,
all except XTAL1)
V
IL
SR -0.5 0.2 V
DD
- 0.1
V
Input low voltage XTAL1
V
IL2
SR -0.5 0.3 V
DD
V
Input low voltage
(Special Threshold)
V
ILS
SR -0.5 2.0 V
Input high voltage (TTL,
all except RSTIN
, XTAL1)
V
IH
SR 0.2 V
DD
+ 0.9
V
DD
+
0.5
V
Input high voltage RSTIN
(when operated as input)
V
IH1
SR 0.6 V
DD
V
DD
+
0.5
V
Input high voltage XTAL1
V
IH2
SR 0.7 V
DD
V
DD
+
0.5
V
Input high voltage
(Special Threshold)
V
IHS
SR 0.8 V
DD
- 0.2
V
DD
+
0.5
V
Input Hysteresis
(Special Threshold)
HYS 400 mV Series resistance
= 0
Output low voltage
2)
V
OL
CC 1.0 V I
OL
I
OLmax
3)
0.45 V I
OL
I
OLnom
3)4)
Output high voltage
5)
V
OH
CC V
DD
-
1.0
V I
OH
I
OHmax
3)
V
DD
-
0.45
V I
OH
I
OHnom
3)4)
Input leakage current (Port 5) I
OZ1
CC ±200 nA 0 V < V
IN
< V
DD