Datasheet
XC167CI-16F
Derivatives
Electrical Parameters
Data Sheet 77 V1.3, 2006-08
Note: The shaded parameters have been verified by characterization.
They are not subject to production test.
Table 22 External Bus Cycle Timing
(Operating Conditions apply)
Parameter Symbol Limits Unit
Min. Max.
Output valid delay for:
RD
, WR(L/H)
tc
10
CC 113ns
Output valid delay for:
BHE
, ALE
tc
11
CC -1 7 ns
Output valid delay for:
A23 … A16, A15 … A0 (on PORT1)
tc
12
CC 116ns
Output valid delay for:
A15 … A0 (on PORT0)
tc
13
CC 316ns
Output valid delay for:
CS
tc
14
CC 114ns
Output valid delay for:
D15 … D0 (write data, MUX-mode)
tc
15
CC 317ns
Output valid delay for:
D15 … D0 (write data, DEMUX-mode)
tc
16
CC 317ns
Output hold time for:
RD
, WR(L/H)
tc
20
CC -3 3ns
Output hold time for:
BHE
, ALE
tc
21
CC 0 8ns
Output hold time for:
A23 … A16, A15 … A0 (on PORT0)
tc
23
CC 1 13 ns
Output hold time for:
CS
tc
24
CC -3 3ns
Output hold time for:
D15 … D0 (write data)
tc
25
CC 1 13 ns
Input setup time for:
READY, D15 … D0 (read data)
tc
30
SR 24 – ns
Input hold time
READY, D15 … D0 (read data)
1)
1) Read data are latched with the same (internal) clock edge that triggers the address change and the rising edge
of RD
. Therefore address changes before the end of RD have no impact on (demultiplexed) read cycles. Read
data can be removed after the rising edge of RD.
tc
31
SR -5 – ns