Datasheet
XC167CI-16F
Derivatives
Electrical Parameters
Data Sheet 59 V1.3, 2006-08
4.2 DC Parameters
Table 11 DC Characteristics (Operating Conditions apply)
1)
Parameter Symbol Limit Values Unit Test Condition
Min. Max.
Input low voltage TTL
(all except XTAL1,
XTAL3)
V
IL
SR -0.5 0.2 × V
DDP
- 0.1
V–
Input low voltage for
XTAL1, XTAL3
2)3)
V
ILC
SR -0.5 0.3 × V
DDI
V–
Input low voltage
(Special Threshold)
V
ILS
SR -0.5 0.45 ×
V
DDP
V
4)
Input high voltage TTL
(all except XTAL1,
XTAL3)
V
IH
SR 0.2 × V
DDP
+ 0.9
V
DDP
+ 0.5 V –
Input high voltage
XTAL1, XTAL3
2)3)
V
IHC
SR 0.7 × V
DDI
V
DDI
+ 0.5 V –
Input high voltage
(Special Threshold)
V
IHS
SR 0.8 × V
DDP
- 0.2
V
DDP
+ 0.5 V
4)
Input Hysteresis
(Special Threshold)
HYS 0.04 ×
V
DDP
–VV
DDP
in [V],
Series resis-
tance = 0 Ω
4)
Output low voltage V
OL
CC – 1.0 V I
OL
≤ I
OLmax
5)
–0.45VI
OL
≤ I
OLnom
5)6)
Output high voltage
7)
V
OH
CC V
DDP
- 1.0 – V I
OH
≥ I
OHmax
5)
V
DDP
-
0.45
–VI
OH
≥ I
OHnom
5)6)
Input leakage current
(Port 5)
8)
I
OZ1
CC – ±300 nA 0 V < V
IN
< V
DDP
,
T
A
≤ 125 °C
±200 nA 0 V <
V
IN
< V
DDP
,
T
A
≤ 85 °C
15)
Input leakage current
(all other
9)
)
8)
I
OZ2
CC – ±500 nA 0.45 V < V
IN
<
V
DDP
Configuration pull-up
current
10)
I
CPUH
11)
–-10µA V
IN
= V
IHmin
I
CPUL
12)
-100 – µA V
IN
= V
ILmax