Datasheet
XC164-32
Derivatives
Electrical Parameters
Data Sheet 66 V1.1, 2006-08
Table 16 VCO Bands for PLL Operation
1)
1) Not subject to production test - verified by design/characterization.
PLLCON.PLLVB VCO Frequency Range Base Frequency Range
00 100 … 150 MHz 20 … 80 MHz
01 150 … 200 MHz 40 … 130 MHz
10 200 … 250 MHz 60 … 180 MHz
11 Reserved