Datasheet
C161S
Electrical Parameters
Data Sheet 39 V1.0, 2003-11
PORT0 configuration current
7)
I
P0H
5)
– -5 µA V
IN
= V
IHmin
I
P0L
6)
-100 – µA V
IN
= V
ILmax
XTAL1 input current I
IL
CC – ±20 µA0 V < V
IN
< V
DD
Pin capacitance
8)
(digital inputs/outputs)
C
IO
CC – 10 pF f = 1 MHz,
T
A
= 25 °C
1) Keeping signal levels within the levels specified in this table, ensures operation without overload conditions.
For signal levels outside these specifications also refer to the specification of the overload current
I
OV
.
2) Valid in bidirectional reset mode only.
3) This specification is not valid for outputs which are switched to open drain mode. In this case the respective
output will float and the voltage results from the external circuitry.
4) These parameters describe the RSTIN
pull-up, which equals a resistance of ca. 50 to 250 kΩ.
5) The maximum current may be drawn while the respective signal line remains inactive.
6) The minimum current must be drawn in order to drive the respective signal line active.
7) This specification is only valid during Reset and Adapt Mode.
8) Not subject to production test, verified by design/characterization.
Table 10 DC Characteristics (Reduced Supply Voltage Range) (cont’d)
(Operating Conditions apply)
1)
Parameter Symbol Limit Values Unit Test Condition
Min. Max.