Datasheet

C161S
Electrical Parameters
Data Sheet 34 V1.0, 2003-11
4.2 Operating Conditions
The following operating conditions must not be exceeded in order to ensure correct
operation of the C161S. All parameters specified in the following sections refer to these
operating conditions, unless otherwise noticed.
Table 8 Operating Condition Parameters
Parameter Symbol Limit Values Unit Notes
Min. Max.
Standard
digital supply voltage
V
DD
4.5 5.5 V Active mode,
f
CPUmax
= 25 MHz
2.5
1)
1) Output voltages and output currents will be reduced when V
DD
leaves the range defined for active mode.
5.5 V Power down mode
Reduced
digital supply voltage
V
DD
3.0 3.6 V Active mode,
f
CPUmax
= 20 MHz
2.5
1)
3.6 V Power down mode
Digital ground voltage
V
SS
0 V Reference voltage
Overload current
I
OV
±5 mA Per pin
2)3)
2) Overload conditions occur if the standard operating conditions are exceeded, i.e. the voltage on any pin
exceeds the specified range (i.e.
V
OV
> V
DD
+ 0.5 V or V
OV
< V
SS
- 0.5 V). The absolute sum of input overload
currents on all pins may not exceed 50 mA. The supply voltage must remain within the specified limits.
Proper operation is not guaranteed if overload conditions occur on functional pins such as XTAL1, RD
, WR,
etc.
3) Not subject to production test, verified by design/characterization.
Absolute sum of overload
currents
Σ|I
OV
| 50 mA
3)
External Load
Capacitance
C
L
100 pF
Ambient temperature
T
A
070°C SAB-C161S
-40 85
°C SAF-C161S
-40 125
°C SAK-C161S