Datasheet

C161K
C161O
Data Sheet 19 V2.0, 2001-01
The capture trigger (timer T5 to CAPREL) may also be generated upon transitions of
GPT1 timer T3s inputs T3IN and/or T3EUD. This is especially advantageous when T3
operates in Incremental Interface Mode.
Note: Block GPT2 is only available in the C161O, not in the C161K.
Figure 6 Block Diagram of GPT2
MCB02938
MUX
2
n
: 1
f
CPU
T5
Mode
Control
2
n
: 1
f
CPU
T6
Mode
Control
T6OTL
T3
CAPIN
T6OUT
U/D
U/D
Interrupt
Request
Interrupt
Request
Interrupt
Request
Other
Timers
Clear
Capture
CT3
GPT2 CAPREL
GPT2 Timer T6
GPT2 Timer T5
n = 2 9