Datasheet
Datasheet 15 Revision 2.5, 2013-05-16
ISOFACE™
ISO1H812G
Electrical Characteristics
4.4 Operating Parameters
Parameter
at T
j
= -25 ... 125°C, V
bb
=15...30V, V
CC
=
3.0...5.5V, unless otherwise specified
Symbol Limit Values Unit Test Condition
min. typ. max.
Common mode transient immunity
1)
1) not subject to production test
dV
ISO
/dt -25 - 25 kV/µs DV
ISO
= 500V
Magnetic field immunity
1)
H
IM
100 A/m IEC61000-4-8
Voltage domain V
bb
(Output interface)
Operating voltage V
bb
11
---
35 V
Undervoltage shutdown V
bb(under)
7
---
10.5
Undervoltage restart V
bb(u_rst)
--- ---
11
Undervoltage hysteresis ΔV
bb(under)
---
0.5
---
Undervoltage current I
bb(uvlo)
---
12.5mAV
bb
< 7V
Operating current I
GNDL
---
10 14 mA All Channels
ON - no load
Leakage output current
(included in I
bb(off)
)
V
Dx
= low, each channel
I
L(off)
---
530µA
Voltage domain V
CC
(Input interface)
Operating voltage V
CC
3.0
---
5.5 V
Undervoltage shutdown V
CC(under)
2.5
---
2.9
Undervoltage restart V
CC(u_rst)
--- ---
3
Undervoltage hysteresis ΔV
CC(under)
---
0.1 ---
Undervoltage current I
CC(uvlo)
---
12mAV
cc
< 2.5V
Operating current I
CC(on)
---
4.5 6 mA