Datasheet
ISOFACE™
ISO1H801G
Electrical Characteristics
Datasheet 13 Version 2.3, 2009-09-16
4.5 Output Protection Functions
Parameter
1) Integrated protection functions are designed to prevent IC destruction under fault conditions described in the data sheet.
Fault conditions are considered as “outside” normal operating range. Protection functions are not designed for continous
repetitive operation.
1)
at T
j
= -25 ... 125°C, V
bb
=15...30V, V
CC
=4.5...5.5V, unless
otherwise specified
Symbol Limit Values Unit Test Condition
min. typ. max.
Initial peak short circuit current limit,
V
bb
= 30V, t
m
= 700µs
T
j
= -25°C
T
j
= 25°C
T
j
= 125°C
I
L(SCp)
0.7
1.4
1.9
A
Repetitive short circuit current limit
3)
T
j
= T
jt
(see timing diagrams)
I
L(SCr)
1.1
Output clamp (inductive load switch off)
at V
OUT
= V
bb
- V
ON(CL)
V
ON(CL)
47 53 60 V
Overvoltage protection V
bb(AZ)
47
Thermal overload trip temperature
2) Higher operating temperature at normal function for each channel available
3) not subject to production test, specified by design
2)3)
T
jt
135 °C
Thermal hysteresis
3)
∆T
jt
10 K
4.6 Reserved
Voltage domain V
CC
(Input interface)
Operating voltage V
CC
4.5 5.5 V
Undervoltage shutdown V
CC(under)
2.5 2.9
Undervoltage restart V
CC(u_rst)
3
Undervoltage hysteresis ∆V
CC(under)
0.1
Undervoltage current I
CC(uvlo)
1 2 mA V
cc
< 2.5V
Operating current I
CC(on)
4.5 6 mA
1) not subject to production test