Datasheet
IR2111
(
S
) & (PbF)
www.irf.com 3
Symbol Definition Min. Typ. Max. Units Test Conditions
V
IH
Logic “1” input voltage for HO & logic “0” for LO 6.4 — — V
CC
= 10V
9.5 — — V
CC
= 15V
12.6 — — V
CC
= 20V
V
IL
Logic “0” input voltage for HO & logic “1” for LO — — 3.8 V
CC
= 10V
— — 6.0 V
CC
= 15V
— — 8.3 V
CC
= 20V
V
OH
High level output voltage, V
BIAS
- V
O
— — 100 I
O
= 0A
V
OL
Low level output voltage, V
O
— — 100 I
O
= 0A
I
LK
Offset supply leakage current — — 50 V
B
= V
S
= 600V
I
QBS
Quiescent V
BS
supply current — 50 100 V
IN
= 0V or V
CC
I
QCC
Quiescent V
CC
supply current — 70 180 V
IN
= 0V or V
CC
I
IN+
Logic “1” input bias current — 30 50 V
IN
= V
CC
I
IN-
Logic “0” input bias current — — 1.0 V
IN
= 0V
V
BSUV+
V
BS
supply undervoltage positive going threshold 7.6 8.6 9.6
V
BSUV-
V
BS
supply undervoltage negative going threshold 7.2 8.2 9.2
V
CCUV+
V
CC
supply undervoltage positive going threshold 7.6 8.6 9.6
V
CCUV-
V
CC
supply undervoltage negative going threshold 7.2 8.2 9.2
I
O+
Output high short circuit pulsed current 200 250 — V
O
= 0V, V
IN
= V
CC
PW ≤ 10 µs
I
O-
Output low short circuit pulsed current 420 500 — V
O
= 15V, V
IN
= 0V
PW ≤ 10 µs
Static Electrical Characteristics
V
BIAS
(V
CC
, V
BS
) = 15V and T
A
= 25°C unless otherwise specified. The V
IN
, V
TH
and I
IN
parameters are referenced to
COM. The V
O
and I
O
parameters are referenced to COM and are applicable to the respective output leads: HO or LO.
mV
mA
V
V
µA
Symbol Definition Min. Typ. Max. Units Test Conditions
t
on
Turn-on propagation delay 550 750 950 V
S
= 0V
t
off
Turn-off propagation delay — 150 180 V
S
= 600V
t
r
Turn-on rise time — 80 130
t
f
Turn-off fall time — 40 65
DT Deadtime, LS turn-off to HS turn-on & 480 650 820
HS turn-off to LS turn-on
MT Delay matching, HS & LS turn-on/off — 30 —
Dynamic Electrical Characteristics
V
BIAS
(V
CC
, V
BS
) = 15V, C
L
= 1000 pF and T
A
= 25°C unless otherwise specified. The dynamic electrical characteristics
are measured using the test circuit shown in figure 3.
ns