Datasheet

Version 2.3 20 19 Nov 2012
CoolSET
®
-F3
ICE3A1065ELJ
Electrical Characteristics
4.2 Operating Range
Note: Within the operating range the IC operates as described in the functional description.
Parameter Symbol Limit Values Unit Remarks
min. max.
VCC Supply Voltage V
VCC
V
VCCoff
26 V
Junction Temperature of
Cont
roller
T
jCon
-25 130 °C Max value limited due to thermal
shut down of controller
Junction Temperature of
Cool
MOS
®
T
jCoolMOS
-25 150 °C
4.3 Characteristics
4.3.1 Supply Section
Note: The electrical characteristics involve the spread of
values within the specified supply voltage and junction
temperature range T
J
from – 25 °C to 130 °C. Typical values represent the median values, which are
related to 25°C. If not otherwise stated, a supply voltage of V
CC
= 18 V is assumed.
Parameter Symbol Limit Values Unit Test Condition
min. typ. max.
Start Up Current I
VCCstart
- 150 250 μA V
VCC
=17V
VCC Charge Current I
VCCcharge1
- - 5.0 mA V
VCC
= 0V
I
VCCcharge2
0.55 0.90 1.60 mA V
VCC
= 1V
I
VCCcharge3
- 0.7 - mA V
VCC
=17V
Leakage Current of
Start Up Cell and CoolMOS
®
I
StartLeak
- 0.2 50 μA V
Drain
= 450V
at T
j
=100°C
Supply Current with
Inactive Gate
I
VCCsup1
- 1.5 2.5 mA
Supply Current with Active Gate I
VCCsup2
- 2.5 4.2 mA I
FB
= 0A
Supply Current in Latched Off
Mode
I
VCClatch
- 250 - μA I
FB
= 0A
Supply Current in
Auto Restart Mode with Inactive
Ga
te
I
VCCrestart
- 250 - μA I
FB
= 0A
Supply Current in Active Burst
Mode
with Inactive Gate
I
VCCburst1
- 450 950 μA V
FB
= 2.5V
I
VCCburst2
- 450 950 μA V
VCC
= 11.5V,V
FB
= 2.5V
VCC Turn-On Threshold
VCC Turn-Off Threshold
VCC Turn-On/Off Hysteresis
V
VCCon
V
VCCoff
V
VCChys
17.0
9.8
-
18.0
10.5
7.5
19.0
11.2
-
V
V
V