Datasheet
Parameter Symbol Values Unit
Supply voltage (overvoltage protection see page 6)
V
bb
43 V
Supply voltage for full short circuit protection
T
j,start
=-40 ...+150°C
V
bb
36 V
Load current (Short-circuit current, see page 6)
I
L
I
L(lim)
1
A
Load dump protection
2)
V
LoadDump
=
V
A
+
V
s
,
V
A
= 13.5 V
R
I
3)
= 2 Ω,
t
d
= 400 ms; IN = low or high,
each channel loaded with
R
L
= 13.5 Ω,
V
Load dump
4
)
60 V
Operating temperature range
Storage temperature range
T
j
T
stg
-40 ...+150
-55 ...+150
°C
Power dissipation (DC)
5)
T
a
= 25°C:
(all channels active)
T
a
= 85°C:
P
tot
3.6
1.9
W
Maximal switchable inductance, single pulse
V
bb
= 12V,
T
j,start
= 150°C
5)
, see diagrams on page 10
I
L
= 2.3 A,
E
AS
= 76 mJ, 0Ω one channel:
I
L
= 3.3 A,
E
AS
= 182 mJ, 0Ω two parallel channels:
I
L
= 4.7 A,
E
AS
= 460 mJ, 0Ω four parallel channels:
Z
L
21
25
30
mH
Electrostatic discharge capability (ESD) IN:
(Human Body Model) ST:
out to all other pins shorted:
acc. MIL-STD883D, method 3015.7 and ESD assn. std. S5.1-1993
R=1.5kΩ; C=100pF
V
ESD
1.0
4.0
8.0
kV
Input voltage (DC) see internal circuit diagram page 9
V
IN
-10 ... +16 V
Current through input pin (DC)
Pulsed current through input pin
6)
Current through status pin (DC)
I
IN
I
IN
I
ST
±0.3
±5.0
±5.0
mA
1)
Operation in current limitation is considered as "outside" normal operating range. Protection functions are not
designed for continuous repetitive operation.
2)
Supply voltages higher than V
bb(AZ)
require an external current limit for the GND and status pins (a 150Ω
resistor for the GND connection is recommended.
3)
R
I
= internal resistance of the load dump test pulse generator
4)
V
Load dump
is setup without the DUT connected to the generator per ISO 7637-1 and DIN 40839
5)
Device on 50mm*50mm*1.5mm epoxy PCB FR4 with 6cm
2
(one layer, 70µm thick) copper area for V
bb
connection. PCB is vertical without blown air. See page 14
6)
only for testing
Data Sheet 4 V1.0, 2007-05-13
Smart High-Side Power Switch