Data Sheet

PROFET
®
BTS 6133D
Parameter and Conditions Symbol Values Unit
at T
j
= 25, V
bb
= 12 V unless otherwise specified
min typ max
Data Sheet Page 6 of 17 Rev. 1.0, 2007-02
Diagnostic Characteristics
Current sense ratio, static on-condition
k
ILIS
= I
L
: I
IS,
I
IS
< I
IS,lim
15)
,
V
IS
<V
OUT
-
5 V, V
bIN
> 4.5 V
K
ILIS
--
10 000 --
IL = 30A, Tj = -40°C:
Tj = +25°C:
Tj = +150°C:
IL = 7.5A, Tj = -40°C:
Tj = +25°C:
Tj = +150°C:
IL = 2.5A, Tj = -40°C:
Tj = +25°C:
Tj = +150°C:
8300
8300
8300
7500
8000
8200
6100
6500
7600
10000
9700
9300
10000
9700
9300
10000
9700
9300
11000
10600
10000
11400
10800
10200
14200
12800
11500
I
IN
= 0 (e.g. during deenergizing of inductive loads):
-- 0 --
Sense current under fault conditions
16)
V
ON
>1V, typ T
j
= -40...+150°C:
I
IS,fault
4.0
5.2 7.5 mA
Sense saturation current
V
ON
<1V, typ T
j
= -40...+150°C:
I
IS,lim
4.0
6.0 7.5 mA
Fault-Sense signal delay after input current positive
slope, V
ON
>1V, T
j
= -40...+150°C
t
delay(fault)
350 650 1200
µs
Current sense leakage current, I
IN
= 0 I
IS(LL)
-- 0.1 0.5
µA
Current sense offset current, V
IN
= 0, I
L
0
I
IS(LH)
-- 1 60
µA
Current sense settling time to I
IS static
after input
current positive slope,
17)
I
L
= 0 20 A, T
j
= -40...+150°C
t
son(IS)
--
250 500
µs
Current sense settling time during on condition,
17)
I
L
= 10 20 A, T
j
= -40...+150°C
t
slc(IS)
--
50 100
µs
Overvoltage protection
I
bb
= 15 mA T
j
= -40...+150°C:
V
Z,IS
63
67
-- V
15)
See also figures 4.x and 6.x on page 13 and 14.
16)
Fault conditions are overload during on (i.e. V
ON
>1V typ.), overtemperature and short circuit; see also truth
table on page 8.
17)
Not subject to production test, specified by design.