Data Sheet
PROFET
®
BTS 6133D
Parameter and Conditions Symbol Values Unit
at T
j
= 25, V
bb
= 12 V unless otherwise specified
min typ max
Data Sheet Page 5 of 17 Rev. 1.0, 2007-02
Protection Functions
11)
Short circuit current limit (Tab to pin 1,5)
12)
Short circuit current limit at V
ON
= 6V
13)
Tj
=-40°C:
Tj
=25°C:
Tj
=+150°C:
I
L6(SC)
--
--
70
110
105
90
140
--
--
A
Short circuit current limit at V
ON
= 12V
Tj(start)
=-40°C:
t
m
=170µs
Tj(start)
=25°C:
Tj(start)
=+150°C:
I
L12(SC)
--
--
45
80
75
60
110
--
--
A
Short circuit current limit at V
ON
= 18V
13)
Tj(start)
=-40°C:
T
j(start)
=25°C:
T
j(start)
=+150°C:
I
L18(SC)
--
--
33
60
55
50
80
--
--
A
Short circuit current limit at V
ON
= 24V
Tj(start)
=-40°C:
t
m
=170µs
Tj(start)
=25°C:
Tj(start)
=+150°C:
I
L24(SC)
--
--
20
40
40
35
60
--
--
A
Short circuit current limit at V
ON
= 30V
13)
Tj(start)
=-40°C:
Tj(start)
=25°C:
Tj(start)
=+150°C:
I
L30(SC)
--
--
15
25
25
25
40
--
--
A
Short circuit shutdown detection voltage
(pin 3 to pins 1,5)
V
ON(SC)
2.5
3.5 4.5 V
Short circuit shutdown delay after input current
positive slope, V
ON
> V
ON(SC),
T
j
= -40...+150°C
min. value valid only if input "off-signal" time exceeds 30 µs
t
d(SC1)
350
650 1200 µs
Short circuit shutdown delay during on condition
13)
V
ON
> V
ON(SC)
t
d(SC2)
--
2 -- µs
Output clamp (inductive load switch off)
14)
at V
OUT
= V
bb
- V
ON(CL)
(e.g. overvoltage)
I
L
= 40 mA
V
ON(CL)
39
42 -- V
Thermal overload trip temperature T
jt
150 175 -- °C
Thermal hysteresis
∆
T
jt
-- 10 -- K
11)
Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are not
designed for continuous repetitive operation.
12)
Short circuit current limit for max. duration of t
d(SC1)
, prior to shutdown, see also figures 3.x on page 13.
13)
Not subject to production test, specified by design.
14)
See also figure 2b on page 12.